Masonry design
We design structural masonry, including reinforced blockwork walls, loadbearing brick and block, masonry retaining walls and lintels. We also assess existing masonry where openings are cut, loads change or cracking appears.
Structural engineering
Typical projects
- Reinforced blockwork walls in commercial and industrial buildings
- Blockwork retaining walls and basement walls
- Loadbearing masonry in townhouses and multi-residential projects
- New openings in existing brick or block walls
Problems this work solves
- Cores that are not filled
- Reinforced blockwork only works if the cores with bars are fully grouted. Missed or partly filled cores are a common site defect and are hard to see after the fact.
- Movement joints
- Masonry cracks if it cannot move with temperature, moisture and the structure around it. Articulation and control joint positions belong in the design, not left to the bricklayer.
- Lateral loads
- Tall freestanding or parapet walls are governed by wind and by how the top of the wall is restrained.
What our engineering covers
Coreline's role is design, documentation, assessment and inspection. Construction, supply and installation sit with the builder and trades.
- Wall design for vertical, wind and retained-soil loads to AS 3700
- Reinforcement, grouting and bond beam details
- Control joint and articulation layout
- Lintel and opening design
- Assessment of existing masonry for alterations
Design considerations
- Blockwork against concrete
- Reinforced blockwork avoids formwork and suits smaller crews, while in-situ or precast concrete walls are faster on long runs. Retaining height and site access usually decide.
- Inspection before grouting
- An inspection of bars before the cores are filled is the only practical check of reinforced masonry, and it should be planned into the programme.
- Weep holes and drainage
- Masonry retaining walls need drainage behind them; water pressure is a common reason they lean or crack.
What you typically receive
The exact deliverables are set in the fee proposal for each project.
- Masonry wall drawings with reinforcement and grouting details
- Control joint layout
- Lintel schedule
- Design certification and inspection certificates where required
What to send us
- Proposed construction sequence and any temporary propping constraints
- Architectural plans and wall elevations
- Wall heights, retained heights and loads above
- Soil test or geotechnical report
- For existing walls: photos, measurements and any cracking observed
Standards and regulations that usually apply
Which documents govern a design depends on the project. These are the ones most often relevant here; we confirm the applicable editions for each job.
- AS 3700
- Design and construction of masonry structures.
- AS/NZS 1170 series
- Structural design actions: permanent, imposed, wind, earthquake and other loads used in every structural design.
- NCC (Building Code of Australia)
- Performance requirements for buildings. In Queensland NCC 2022 applies until 30 April 2027 and NCC 2025 from 1 May 2027.
Questions we are asked
Can I cut a new opening in a brick wall?
Often yes, with a lintel designed for the load above and a check that the wall either side can take the concentrated reactions. On loadbearing walls the opening and temporary propping need engineering before work starts.
Why is my blockwork wall cracking at regular spacing?
Regular vertical cracks usually point to missing or badly placed control joints, letting shrinkage and thermal movement crack the wall. An inspection can confirm whether it is movement cracking or something structural.
Do reinforced block walls need an inspection?
Yes. An engineer or certifier should inspect the reinforcement before the cores are grouted, because once grouted there is no practical way to check it.